<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:sy="http://purl.org/rss/1.0/modules/syndication/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0">
  <channel>
    <title>Iranian Journal of Power Engineering</title>
    <link>https://ijpe.birjand.ac.ir/</link>
    <description>Iranian Journal of Power Engineering</description>
    <atom:link href="" rel="self" type="application/rss+xml"/>
    <language>en</language>
    <sy:updatePeriod>daily</sy:updatePeriod>
    <sy:updateFrequency>1</sy:updateFrequency>
    <pubDate>Thu, 01 Oct 2026 00:00:00 +0330</pubDate>
    <lastBuildDate>Thu, 01 Oct 2026 00:00:00 +0330</lastBuildDate>
    <item>
      <title>A Sliding Mode Voltage Controller and a Lyapunov-Based Current Controller for a Bridgeless Boost PFC</title>
      <link>https://ijpe.birjand.ac.ir/article_3816.html</link>
      <description>In this paper, a bridgeless boost PFC (BBPFC) with a 2nd order sliding mode controller (SMC) as a voltage controller and a Lyapunov-based current controller is proposed. Using a bridgeless structure leads to less power dissipation due to the elimination of the diode bridge. Moreover, since the boost inductor operates as EMI filter, as well, the implementation costs and difficulties will decrease. On the other hand, a second order SMC is used to attenuate the voltage ripples and chattering. Since the voltage loop has no direct influence on the switching signal, the chattering problem will be mitigated significantly and high-frequency ripples will not appear in the gate signal of the converter. In addition, by using a Lyapunov-based current controller, the stability of the current controller is guaranteed. The experimental prototype of the system is provided. Experimental results show that BBPFC with SMC and Lyapunov-based controllers gives satisfactory results in improving the power quality of the input current.</description>
    </item>
    <item>
      <title>A Novel Protection Method for Radial Distribution Systems with Distributed Generation Using Directional Relays and Smart Coordination</title>
      <link>https://ijpe.birjand.ac.ir/article_4349.html</link>
      <description>Conventional overcurrent protection schemes for radial distribution systems typically coordinate a recloser at the beginning of the feeder with lateral fuses. Integrating Distributed Generation (DG) into distribution systems introduces complex challenges in protective coordination that conventional methods struggle to address effectively. In this paper, we propose a new protection scheme that replaces reclosers along the line with conventional directional overcurrent relays. The proposed strategy ensures protection selectivity, whether or not DG units are connected to the network. The scheme supports both fuse-saving and fuse-blowing approaches, providing flexibility depending on operational needs. The protection system's performance is designed to ensure effective operation during network-connected or islanded modes. This flexibility makes it suitable for modern distribution systems with a high penetration of distributed energy resources. Additionally, the scheme can enhance reliability and reduce unnecessary disconnections, thus maintaining network stability. To evaluate the effectiveness of the proposed scheme, detailed assessments were conducted on a representative distribution system. Simulations were performed using Digsilent software, demonstrating the practicality and benefits of the new approach for improving system reliability and maintaining protective coordination in diverse scenarios.</description>
    </item>
    <item>
      <title>Optimal Fuzzy Sliding Mode Control Design for Practical DC Motor by Utlizing Jaya Algorithm</title>
      <link>https://ijpe.birjand.ac.ir/article_4341.html</link>
      <description>In this study, an optimal fuzzy sliding mode control (OFSMC) is proposed for the speed and position of a DC motor. For robustness against external disturbance and parameter uncertainty, sliding mode control (SMC) is offered. To improve the effectiveness of the SMC and to decrease the chattering effects, fuzzy logic systems are combined with the proposed sliding mode controller. Moreover, by utilizing of Jaya Optimization Algorithm, the parameters of the suggested controller are optimized. By using Jaya Algorithm, the sliding surface of controller is tuning online that has more benefits in versuse of constant gains. As expecting OFSMC is the best control performance (lower error values) among other suggested controllers that merits of applying the Jaya optimization algorithm for the optimization of the sliding surface gains system are apparent. In following, by utilizing the Lyapunov stability theorem closed-loop system stability is proved. Finally, the experimental results have denoted the merits of the suggested controller.</description>
    </item>
    <item>
      <title>The Impact of Feeder Impedance on the Status of Disconnection of Photovoltaic System Under Single Short-circuit Fault in Asymmetric Low Voltage Distribution Network</title>
      <link>https://ijpe.birjand.ac.ir/article_4352.html</link>
      <description>Abstract-- This paper presents an analysis of the feeder voltage profile and the status of the disconnection of photovoltaic systems after a single-phase short circuit fault in a 400 V low voltage feeder. The paper aims to evaluate and discuss the feeder impedance on the status of the disconnection of photovoltaic systems in a real asymmetric distribution network with 100% penetration level. The analysis was intended to figure out the conditions under which systems in the feeder may fail to disconnect after a single-phase short circuit fault or keep feeding the network. Simulations were carried out in the DIgSILENT software environment and the results were reported and analyzed. The results indicate that the change in the absolute value of the feeder impedance does not affect the system disconnection. Still, the change in the resistance ratio to the reactance of the feeder impedance affects the system disconnection status in some phases.</description>
    </item>
    <item>
      <title>Automation in Service Restoration of Distribution Networks Using Scheduling of Multiple Resources</title>
      <link>https://ijpe.birjand.ac.ir/article_4353.html</link>
      <description>The service restoration (SR) problem has always been one of the most challenging issues in the operation and automation of electrical distribution networks. With the increasing development of the distribution network and the introduction of various new technologies and facilities, and the need for automation of distribution networks, solving this problem requires much more efficient and faster solutions. In this paper, a new method is proposed to solve the SR problem. The distribution network in this study has many resources including mobile power sources (MPS) and repair crew (RC) that are scheduled simultaneously. This article also pays attention to how to incorporate traffic considerations of the transportation network into the problem, which adds to its applicability. The service restoration problem in this paper is modeled as a MILP problem and solved by mathematical solvers. This ensures the achievement of optimal and fast solutions. The proposed method was used on a 33-bus test network and its efficiency was proven.</description>
    </item>
    <item>
      <title>Comparison of Various Aspects of Neutral Point Clamped and Cascaded H-Bridge Inverters for Use in Photovoltaic Systems</title>
      <link>https://ijpe.birjand.ac.ir/article_4356.html</link>
      <description>Among the various inverter structures, multilevel inverters are widely used in photovoltaic systems today due to their numerous advantages. However, different performance indicators provide multiple options for photovoltaic systems, each with specific strengths and limitations. In this paper, two common topologies&amp;amp;mdash;Neutral Point Clamped (NPC) and Cascaded H-Bridge (CHB)&amp;amp;mdash;are evaluated at five and nine levels. The comparison covers several criteria including structural complexity, number of components, type of DC sources, electrical losses, weight, and cost. In addition, performance-related indicators such as Total Harmonic Distortion (THD) and compliance with grid-connection standards are studied. Simulation-based evaluations were conducted using Matlab, with an induction motor used as a reference load to analyze losses under varying mechanical conditions. Filtering requirements were also considered to ensure THD remains below the 5% threshold. Ultimately, the results show that although increasing the number of voltage levels improves output quality, it significantly increases the weight and cost. After including the filter design, the 5-level NPC inverter demonstrated the best overall performance, offering a suitable balance of efficiency, compliance, cost, and structural simplicity for photovoltaic applications.</description>
    </item>
    <item>
      <title>Optimal design of medium voltage distribution networks based on possible risk criteria to increase reliability - Part I: Redesigning the existing network</title>
      <link>https://ijpe.birjand.ac.ir/article_4274.html</link>
      <description>In this paper, a part of the results from the research project entitled &amp;amp;lsquo;Optimal Design of Medium Voltage Distribution Networks Based on Risk Criteria to Enhance Reliability&amp;amp;rsquo; is presented. The purpose of this research is to develop a methodology for optimally and resiliently designing distribution networks within a probabilistic framework, by incorporating uncertainties in input parameters to enhance network reliability. In solving the problem, the three main questions, namely location, time and capacity of each of the important elements of the medium voltage network, will be answered in the presence of these uncertainties. In this approach, three key questions in the design of medium-voltage distribution networks are examined: the optimal location of key network elements, the appropriate time for equipment expansion or replacement, and the appropriate capacity of each network component. These questions are analyzed in the presence of various uncertainties including load demand, renewable energy source output, equipment reliability, and environmental conditions. The results show that the proposed approach can significantly improve the overall reliability of the distribution network while reducing operational and financial risk. This method performs better than traditional deterministic design methods, especially in conditions of high uncertainty.</description>
    </item>
    <item>
      <title>Designing Medium Voltage Distribution Networks Based on Probabilistic Risk Criteria to Improve Network Reliability &amp;ndash; Part II: A Study on Load Uncertainty and Distributed Generation</title>
      <link>https://ijpe.birjand.ac.ir/article_4273.html</link>
      <description>This study presents the optimal placement of automatic power switches in the distribution network of Tabriz city, considering distributed generation sources and uncertainties arising from load forecasting and renewable energy generation. Given the urban context of the design scope, photovoltaic source penetration is prioritized. The design focuses on optimally positioning remote control switches (RCS) to enhance network reliability and meet automation objectives. For this purpose, an interface has been created to use the optimization force of MATLAB software and the technical computing force of DIgSILENT software. In this case, system index&amp;amp;rsquo;s are calculated in DIgSILENT software for each scenario in MATLAB, and by calculating the cost probability distribution function, the level of riskiness of the system is evaluated according to the number of installed switches. Due to the large volume of study results, a part of the studies and research results will be presented in this article.</description>
    </item>
    <item>
      <title>Smart Energy Management of Electric Vehicle Parking Lots within Dynamic Electricity Market</title>
      <link>https://ijpe.birjand.ac.ir/article_4361.html</link>
      <description>In this paper, the problem of decision making for an electric vehicle parking lot during a short-term time horizon in a competitive environment is modeled as a bi-level problem. Several electric vehicle parking lots compete with each other in a competitive space to supply energy to vehicles. Electricity market prices, the bidding prices of competing parking lots, and the stochastic nature of drivers' behavior transform the decision-making problem into a probabilistic one. Therefore, the proposed problem is formulated probabilistically and in two levels. In the first level, the electric vehicle parking lot seeks to maximize its profit by participating in the short-term power pool market, including day-ahead and balancing markets. The second level there are electric vehicle owners who try to supply their required energy from the cheapest aggregator. The results show the impact of risk averse behavior of aggregators on the energy purchased from the network in day ahead and balancing markets.</description>
    </item>
    <item>
      <title>Dynamic analysis of the governor control system of a 25 MW Hitachi gas-fired power plant for designing a load shedding system</title>
      <link>https://ijpe.birjand.ac.ir/article_4246.html</link>
      <description>This report was prepared regarding design of the Power management system of one of the country's refineries and was compiled based on the information of the 25 MW frame 5 Hitachi gas power plant. 3 power plants were installed and commissioned by Hitachi and the 4th power plant installed and commissioned by us, and these power plants have similar dynamic behavior. Total consumed power of refinery plant will produced by these power plants and there is no external point of common coupling (PCC) in the field. In this report, the behavior of the power plant is examined and analyzed and conventional strategies for load shedding, investigation and the best strategy that can be implemented and executed in this power plant are proposed. In compiling this report, MATLAB software has been used for numerical calculations and graphic drawing. The various load shedding scenarios are considered and suitable scenario for the petrochemical refinery which is frequency based load shedding was selected. Grouping the loads and determination of the critical and non- critical loads was selected as operator guide lines.</description>
    </item>
    <item>
      <title>Voltage Positive-Feedback Based Islanding Detection in Photovoltaic Systems Using Fuzzy Controller</title>
      <link>https://ijpe.birjand.ac.ir/article_4247.html</link>
      <description>In general, microgrids can be operated in two modes: grid-connected and grid-disconnected. As a small-scale power system, microgrids can achieve the basic objective of the power grid, including reducing losses, increasing reliability, reducing emissions, and saving economic. When the microgrid is connected to the grid, the sharing of active and reactive power and its supply to the consumer is done with greater reliability and higher quality. Sometimes, events occur in the grid that disconnect the grid-connected microgrid from the main grid, which is called microgrid islanding. When the microgrid becomes islanded, it must independently supply local loads. The time of islanding detection is of great importance so that timely and rapid detection can reduce the losses caused by the separation of the microgrid from the main grid. There are various methods for detecting islanding of a microgrid based on solar modules, in this study, the method based on positive voltage feedback is used. The presented method is based on the measurement of parameters from the PCC point and can be analyzed. In this method, based on the feedback taken from the voltage amplitude at the PCC point, the analysis of microgrid islanding is presented based on the fuzzy controller. The simulation is performed in MATLAB software and on the sample system.</description>
    </item>
    <item>
      <title>Design of Outdoor Insulation Sheds of ZnO Surge Arresters Aiming at Electric Field Distribution on Surface ZnO Pills Column Using 2-D FEM and Fuzzy Multiobjective</title>
      <link>https://ijpe.birjand.ac.ir/article_4249.html</link>
      <description>In this paper, the optimal design of a metal oxide surge arrester with appropriate distribution of electric field of the Zinc Oxide pills using intelligent algorithms and numerical analysis of 2-dimenional Finite Element Method (FEM) is studied in electrostatic situation. This paper has presented a fuzzy multiobjective model and DE and PSO algorithms to prevention of premature aging of ZnO pills column. This formulation incorporates two objectives: minimization of maximum of electric field on ZnO column surface and minimization of porcelain housing volume. Parameters of designing are length and thickness outdoor insulation sheds. The proposed approach used for two case for to valuation objectives. With uniform distribution of the electric field, the ZnO pills lifetime increases and the cost of operation and maintenance decreases. Also, by reducing the volume of porcelain insulation, the manufacture cost of surge arrester reduces. All other requirements and constraints that must be considered in the design of insulation elements are also satisfied.</description>
    </item>
    <item>
      <title>Unit Commitment Problem Solution Using Seeker Optimization Algorithm</title>
      <link>https://ijpe.birjand.ac.ir/article_4251.html</link>
      <description>Unit commitment (UC), a critical power system operation problem, involves high complexity due to numerous constraints. This paper presents a novel approach using the seeker optimization algorithm (SOA), an evolutionary method inspired by human search behavior. The proposed SOA employs integer coding to efficiently handle minimum up/down constraints and binary coding for spinning reserve requirements. By leveraging population-based search, SOA ensures optimal convergence while addressing UC&amp;amp;rsquo;s combinatorial challenges. Simulations across diverse test systems demonstrate algorithm superiority in convergence speed and solution quality compared to conventional methods. The integer-coded framework enhances computational efficiency, particularly in managing unit minimum uptime/downtime constraints. Results implemented on 10 to 100 generating units validate SOA&amp;amp;rsquo;s effectiveness in optimizing large-scale UC problems, compared to the other existing approaches, offering a reliable tool for power system operators. This approach bridges the gap between metaheuristic adaptability and UC&amp;amp;rsquo;s rigid constraints, paving the way for cost-effective and operationally feasible solutions.</description>
    </item>
    <item>
      <title>Intelligent Load Frequency Control in Multi-Area Power Systems through Brain Emotional Learning</title>
      <link>https://ijpe.birjand.ac.ir/article_4259.html</link>
      <description>In conventional control techniques based on power system linearization around a given point, outputs are dissatisfactory under sudden variations in load and displacement of the working point. Therefore, several methods have been introduced to adapt such controllers to variations in system operations. This paper proposes an intelligent load frequency control (LFC) technique for multi-area power systems with an emotional neural network (ENN), the parameters of which are tuned through the particle swarm optimization (PSO). The proposed emotional learning-based intelligent controller is inspired by the mammalian brain limbic system in light of its effectiveness and efficiency in control applications. Simulations were performed in MATLAB on an intrinsically nonlinear three-area power system under sudden load and parameter changes. The proposed model was compared to classical proportional&amp;amp;ndash;integral&amp;amp;ndash;derivative (PID), standard ENN, and indirect adaptive fuzzy controllers under various operating conditions and parameter changes. According to the results, the proposed methodology was faster and more accurate in controlling frequency variations and power transfer changes between power system areas. The main novelty of this work lies in the integration of a continuous radial basis emotional neural network (CRBENN) with a Lyapunov-based direct adaptive robust control framework (DARENC), optimized via PSO, for load frequency control in multi-area power systems under uncertainties. The key novelty of this work lies in the integration of a continuous radial basis emotional neural network (CRBENN) with a Lyapunov-based direct adaptive robust control framework (DARENC), optimized via PSO, for load frequency control in multi-area power systems under uncertainties.</description>
    </item>
    <item>
      <title>Fuzzy Logic Charge Control of Li-Ion Batteries Based on SOC Estimation</title>
      <link>https://ijpe.birjand.ac.ir/article_4260.html</link>
      <description>Efficient and reliable charging of lithium-ion batteries remains a critical challenge due to their sensitivity to overcharge and over-discharge, which can significantly reduce lifetime and safety. Traditional fast-charging techniques often rely on high current injection to achieve rapid charging, but require precise control to avoid damaging the cells. To address this challenge, intelligent control strategies have been increasingly explored. In this paper, a fuzzy-logic-based charging controller is developed to regulate the charging current according to the estimated State of Charge (SOC). The SOC is estimated using an Extended Kalman Filter (EKF), where a radial-basis function neural network (RBFNN) is employed to model the nonlinear battery dynamics. This hybrid approach enables accurate SOC tracking under dynamic operating conditions while maintaining computational efficiency. The proposed controller is implemented and experimentally validated on a lithium-ion battery with a capacity of 1.5 Ah, demonstrating high charging speed and robust performance with a good accuracy.</description>
    </item>
    <item>
      <title>Intelligent Coordination of Directional Relays for Protection of Radial Distribution Systems with Integrated Distributed Generation</title>
      <link>https://ijpe.birjand.ac.ir/article_4284.html</link>
      <description>The integration of Distributed Generation (DG) into radial distribution networks introduces significant challenges for traditional overcurrent protection schemes, particularly with respect to relay&amp;amp;ndash;fuse coordination and fault selectivity. Variations in both the direction and level of fault currents caused by DG units can compromise the reliability of conventional recloser-based protection strategies. To address these challenges, this paper proposes an alternative protection approach in which directional overcurrent relays are deployed along the feeder, eliminating the dependence on a single recloser at the substation. The proposed scheme ensures selective fault isolation under different DG operating conditions and supports both fuse-saving and fuse-blowing protection philosophies. Unlike conventional approaches, the coordination logic remains effective regardless of the connection or disconnection status of DG units. The effectiveness of the proposed protection strategy is demonstrated through detailed time-domain simulations carried out on a representative radial distribution network using DIGSILENT PowerFactory. Simulation results confirm that the proposed method enhances coordination robustness and fault selectivity while maintaining compatibility with existing distribution protection infrastructure.</description>
    </item>
    <item>
      <title>Intelligent Fault Diagnosis of an Industrial Mixer Motor Using a Multi-Layer Perceptron Neural Network Based on PLC and Vibration Data</title>
      <link>https://ijpe.birjand.ac.ir/article_4285.html</link>
      <description>--Reliable condition monitoring and timely fault diagnosis of industrial electric motors play a vital role in ensuring operational efficiency and reducing unplanned downtime in manufacturing systems. In this study, a data-driven intelligent framework is proposed for detecting bearing faults in an industrial mixer motor utilized in a tire production line. The approach employs a Multi-Layer Perceptron (MLP) neural network trained on a hybrid dataset obtained from both vibration sensors and Programmable Logic Controller (PLC) records. Comprehensive preprocessing was performed, including denoising, signal normalization, and extraction of statistical features such as root mean square (RMS), kurtosis, and crest factor to enhance feature representation. The MLP model, implemented in Python using the backpropagation algorithm and ReLU activation function, was trained and validated under four operational conditions: healthy, inner race fault, outer race fault, and ball fault. Model performance was assessed using confusion matrix, accuracy, F1-score, and receiver operating characteristic (ROC) metrics. The experimental results revealed that the MLP network achieved a classification accuracy of 90.33%, demonstrating high robustness and stability in noisy industrial environments. The proposed framework can be effectively adopted as a practical tool for predictive maintenance and intelligent condition monitoring of industrial rotating machinery</description>
    </item>
  </channel>
</rss>
